Woods Freezer. sourcing parts

I am in need of a replacement thermostat for my Woods Medalist upright freezer. model V350. Type MBOAA2. other numbers on the unit are : CC12F2 (R12) 227

Numbers found on the thermostat itself include : Ranco K50/K54 – K57/K59
81-35-7P YPE-K50-P 1168
4 30733.005

Local shop want $ 109 and would take four to six weeks, anyone know of a good appliance parts shop that could help out ? thanks in advance.


Source: New feed

Continue Reading

RF195ADUX1 Code F20 (broken wire) in Fisher Paykel. Can't even order new door?

Code F20 means low current to flapper heater, caused by either an open heater element or broken wire. In my case, tech diagnosed a broken wire, but the wire is moulded into the door foam and the entire door needs to be replaced.

Unfortunately, it appears Fisher Paykey no longer sells a replacement door now!

Anyone found a work-around for this or contacted the company?


Source: New feed

Continue Reading

Need Expert advice on converting to hang a whole deer in

I know this is a little lengthy but maybe someone can help. I saw many years ago someone who had a fridge.. freezer standard on top.. he had removed the floor of the freezer (ceiling of fridge) and made one huge unit. He then hung hangers from the roof of the now one chamber unit and now had a meat hanging fridge.
I want to create one of these and am searching for some used fridges. My problem is.. how do I know if the fridge I am looking at has the freezing elements and tubing in the actual floor of the freezer.. therefore not allowing me to remove the floor.. as opposed to one whose tubing and so forth is all in the walls etc.. so I can remove the floor. What am I looking for? I want to have a unit I can hang a whole deer in. Thank you


Source: New feed

Continue Reading

GE Profile Side by Side doesn't cool at all

About a 2 weeks ago we noticed the fridge not cooling as well as we liked. It gradually got worse. Then for two days it worked perfectly. Then the temperature on the fridge side started rising but the freezer was only a little warmer than normal. I removed the panel in the back of the freezer and noticed ice and frost on the lower side of the coils. I thawed them out with a hair dryer. The temperature continued to rise to the point that it seemed nothing was working. It had stopped cooling completely. I removed the back panel to expose the compressor and motherboard. The compressor did not seem to be running right. Sometimes it would start and sometimes it wouldn’t. The voltage from the motherboard to the inverter board was fluctuating rapidly from 4 to 6 volts DC. The winding’s in the compressor seemed to check out okay. If I unplugged the fridge then plugged it back in the compressor would sometimes start and sometimes not. I replaced the inverter board and no change. I replaced the motherboard and the DC voltage was just under 6 volts dc and no longer fluctuated. The compressor and fan seemed to start normally but was unusually quiet. I let it run for 24 hours and it did not cool at all. No frost, ice, or anything. The compressor still doesn’t seem to be working properly

Help!!!


Source: New feed

Continue Reading